Performance Evaluation of a Thermal Energy Storage

Article Preview

Abstract:

The direct contact heat transfer technique gives better heat transfer rates. In this paper, the operation of a simple system was simulated under different operating conditions. During the charging mode of the operation, refrigerant R134a is injected into water stored in an evaporator to exchange directly heat with the water and form clathrates. Later, the clathrate is used to cool water which is used for air-conditioning purposes. Direct contact charging and/or discharging eliminate the necessity of a heat exchanger inside the storage tank and leads to an effective heat transfer method. The results indicate that the performance of the system depends on the refrigerant type, compressor speed and the mass flow rate of the refrigerant.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

642-647

Citation:

Online since:

February 2013

Export:

Price:

Сopyright:

© 2013 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

[1] Abhat A. Low Temperature Latent Heat Thermal Energy Storage: Heat Storage Materials. Solar Energy (1983); 30: 313-332.

DOI: 10.1016/0038-092x(83)90186-x

Google Scholar

[2] Wettermack, G. and Kowalewski, J., Storage of Low Temperature Heat: Solar Energy Thermal Storage, Swedish council for Building Research, (1976).

Google Scholar

[3] Lorsch HG, Kauffman KW, Denton JC, Thermal Energy Storage for Heating and Air-conditioning, Future Energy Production System. Heat Mass Transfer Process, (1976); pp.69-85.

Google Scholar

[4] Lane GA, Glew DN, Clark EC, Rossow HC, Quigley SW, Drake SS et al. Heat of Fusion for Solar Energy Subsystem for Heating and Cooling of Buildings, Charlottesville, Virginia, USA. (2004).

Google Scholar

[5] Scot MD. Large Water Side Temperature Differentials Enhance Existing TES System Performance. Energy Engineering; (1988).

Google Scholar

[6] Dincer I. On Thermal Energy Storage Systems and Applications in Buildings. Journal of Energy & Buildings; (2002); 34: 377-388.

DOI: 10.1016/s0378-7788(01)00126-8

Google Scholar

[7] Dincer I, Rosen MA. Thermal Energy Storage Systems and Applications. John Wiley & Sons; (2002).

Google Scholar

[8] Haughey MD. Ice Thermal Storage for Colorado School. ASHRAE Journal (2003); 45: 50-53.

Google Scholar

[9] Beggs CB, Ward IC. Ice Storage: Design Study of the Factors Effecting Installations. Journal of Building Services Eng Res Technol (1992); 13: 49-59.

DOI: 10.1177/014362449201300201

Google Scholar

[10] T. Kiatsiriroat, N. Vorayos, S. Vithayasai, A. Nuntaphan, N. Vorayos, Heat Transfer Prediction for a Direct Contact Ice Thermal Energy Storage, EnergyConversion & Management 44 (2003) 497–508.

DOI: 10.1016/s0196-8904(02)00077-8

Google Scholar

[11] Habeebullah BA. Economic Feasibility of Thermal Energy Storage Systems. Journal of Energy & Buildings (2007); 39: 355-363.

DOI: 10.1016/j.enbuild.2006.07.006

Google Scholar

[12] Kulish MA. Utility-Controlled Customer Side Thermal Energy Storage. Oak Ridge National Laboratory; (1983).

Google Scholar

[13] Tadaaki, M. and Yoshimasa A. Low Temperasture Heat Storage Type (Use of Clathrates), TVA, USA, (2009).

Google Scholar

[14] Carbajo, J. J., Mixed Clathrate for Cool Storage Applications, Oak Ridge National Laboratory, July, (1987).

Google Scholar