Active Power Losses in Pressure Rings for Contact Shoes of Ore-Thermal Furnace

Article Preview

Abstract:

Results of electromagnetic problem solution for three-phase electrodes system in ore-thermal furnace for electrodes equivalent electric circuit parameters calculation made by using 3D-models in numerical finite element method program package ANSYS are presented. Contact shoes pressure rings and heat shield of energy feeding unit are taken into account.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

57-60

Citation:

Online since:

December 2014

Export:

Price:

* - Corresponding Author

[1] Dancys Y. B. Korotkie seti i elektricheskie parametry dugovyh elektropechei. Moskva: Metallurgiia, 1987. (in Russian).

Google Scholar

[2] Aliferov A. I., Bikeev R. A., Vlasov D. S., Research of influence of metal constructions of electric furnaces on their electrical parameters, The 8 international forum on strategic technologies (IFOST 2013) : proc., Mongolia, Ulaanbaatar, 2013, Vol. 1, pp.279-282.

Google Scholar

[3] Aliferov A. I., Blank A.V., Bikeev R. A., Issledovanie vliianiia metallicheskikh konstruktcii elektricheskikh pechei na ih elektricheskie parametry, Izvestiia vysshih uchebnyh zavedenii. – Elektromehanika, 2013, №6, p.36 – 40. (in Russian).

Google Scholar