Mechanical Properties of Bamboo Fibre Composite Incorporating Pulverized Fuel Ash

Article Preview

Abstract:

This study reports the findings of an experimental investigation for bamboo fibre (BF) reinforced concrete board. In this research, all specimens were prepared at 0.4 water/binder ratio. There were two series of specimens namely A series and B series. The A group utilizes only ordinary portland cement (OPC) as binder. Meanwhile, series B specimens uses binary binders, which were combination of OPC and pulverized fuel ash (PFA) with PFA to OPC ratio of 0.2. The performance of flat board plates with different percentage of bamboo fiber ranging from 0% to 5% and 20% PFA incorporation of cement weight were tested for bending strength (flexural) and compressive strength in accordance to BS 5669: Part 1 for particleboards. Specimens are cured in water curing tank and tested at 3, 7 and 28 days for compression test. Meanwhile for flexural strength test, the specimens are tested at 28 days. It is found that flexural and compressive strength increases with addition of BF. The optimum compressive and flexural strength at 28 days are recorded with 3% incorporation of BF for both PFA and control samples. Therefore, utilizing natural fibre and waste material for partial substitution of cement content in producing internal wall paneling system could contributes to the economic appeal and promoting sustainable construction approach.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

270-274

Citation:

Online since:

July 2015

Export:

Price:

Сopyright:

© 2015 Trans Tech Publications Ltd. All Rights Reserved

Share:

Citation:

* - Corresponding Author

[1] M.H.M. Hashim: Coconut Fiber Reinforced Wall Panelling System. University of Technology Malaysia, Skudai, Johor, Malaysia , (2005), pp.1-12.

Google Scholar

[2] S. Amada and S. Untao: Fracture Properties of Bamboo, Compos. Mater., Part B. Eng. 32, (2001), p.449–457.

Google Scholar

[3] K. Ghavami, R.D.T. Filho and N.P. Barbosa: Cement and Concrete Compos. Vol. 21 (1999), pp.39-48.

Google Scholar

[4] E. Alvarez-Ayuso, X. Querol, F. Plana, A. Alastuey, N. Monero, M. Izquierdo, O. Font, T. Monero, S. Diez, E. Vazquez, and M. Barra:, Journal of Hazardous Mater. Vol. 154 (2008), pp.175-183.

DOI: 10.1016/j.jhazmat.2007.10.008

Google Scholar

[5] BS 812-103. 2, Testing Aggregates. Method for Determination of Particle Size Distribution, Sedimentation Test (1989).

Google Scholar

[6] British Standards Institution, Particleboard, Method of sampling, Conditioning and Test. London, BS5669: Part 1 (1989).

Google Scholar

[7] R. Sudin, R.N. Swamy: Journal. Mater. Sci. Vol. 41 (2006), pp.6917-6924.

Google Scholar

[8] M. Ramli, and E.T. Dawood: American Journal of Engineering and Applied Sci. (2010), pp.489-493.

Google Scholar

[9] A. Zuraida, S. Norshahida, I. Sopyan and H. Zahurin: IIUM Engineering Journal Vol. 12 (2011), pp.63-75.