Abstract:

Thermoacoustic Heat Engine probably the most efficient energy source for electronic devices for the next 10 year ahead that require small amount of electrical energy to operate. This study was to simulate the Thermoacoustic Heat Engine (TAHE) standing wave system by conducting a Fluid Structure Interaction (FSI) by using a Thermoacoustic system’s software named DeltaEC for better uderstanding on the fundamental of TAHE standing wave system. Some characteristics or parameters in the system that were studied in order to derive the fundamental knowledge of TAHE standing wave system. The thickness of Hot Heat Exchangers (Hot HX) plays the major role in affecting the maximum acoustic power generated, the level of onset temperature difference and maximum pressure amplitude followed by the stack length. Hot HX dimension (thickness) contributes nearly 3.3% changes in maximum acoustic power where the lowest thickness scores the highest maximum acoustic power generated. 2.9% of increment on maximum acoustic power generated by altering the length of the stack by 5 mm.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

311-316

Citation:

Online since:

August 2015

Export:

Price:

* - Corresponding Author

[1] D.L. Gardner and C.Q. Howard, Waste heat driven thermoacoustic engine and refrigerator. Proceeding of Acoustic, Adelaide Australia. (2009) 23-25.

Google Scholar

[2] N. Stuban and A. Torok, Utilization of exhaust gas thermal energy-theoretical investigation. 33rd Int. Spring on Electronics Technology, IEEE (2010) 268-272.

DOI: 10.1109/isse.2010.5547301

Google Scholar

[3] X. Kan, F. Wu and L. Chen, Contractual of regenerator in a thermo-acoustic engine, Int. J. Of Sustainable Energy 29 (2010) 211-219.

DOI: 10.1080/14786461003777732

Google Scholar

[4] K.T. Feldman, Review of the literature on Sondhauss Termoacoustic Phenomena, J. of Sound Vib. 7 (1968) 71.

Google Scholar

[5] M.A. Nouh, N.M. Arafa, K. Larsson and E.A. Rahman, Design Study of Anharmonic Standing Wave Thermoacoustic Heat Engine. The 16th Int. Congress on Sound and Vib. (2009).

Google Scholar

[6] J. Smoker, M. Nouh and O. Aldraihem, Energy harvesting from standing wave thermo-acoustic piezoeletric resonator, American Institute of Aeronautical and Astronautics (AIAA). (2010).

DOI: 10.2514/6.2010-3066

Google Scholar

[7] G.W. Swift, Thermoacoustic engine. J. Acosutic Soc. Am. 84 (1988) 1145-1180.

Google Scholar

[8] G.W. Swift, Thermoacoustics: A unifying perspe ctive for some engines and refrigerators. Condensed Matter and Thermal Physics Group Los Alamos National Laboratory, (2001).

Google Scholar

[9] O.G. Symko, Acoustic approach to thermal management: Miniature thermoacoustic engines. IEEE Transaction. (2006).

Google Scholar

[10] Y. Ueda and Y. Aoi, Critical temperature ratio needed for a spontaneous gas oscillation in a miniature thermoacoustic engine, Proceedings of 20th International Congress on Acoustic, (2010).

Google Scholar

[11] C. Wantha and K. Assawamartbunlue, The impact of the resonance tube on performance of a thermoacoustic stack, Frontiers in Heat Transfer (FHMT). (2011) 1-8.

Google Scholar

[12] Y.W. Liu and Y.L. He, Experimental investigation of a thermoacoustic prime mover with helium-argon mixtures as working gas. J. Power and Energy. (2012) 1-9.

Google Scholar

[13] Montgomery PJ, Low cost thermoacoustic cogenerator for use in biomass burning cook stoves. M. Sc. Thesis, The Pennsylvania State University, USA, (2010).

Google Scholar

[14] A. Sarode, V. Dighe, V. Ingle, and N Kolekar, Theoretical investigation on standing wave thermoacoustic prime mover using Delta EC, International Journal of Research in Engineering and Technology (IJRET), (2014) 562-568.

DOI: 10.15623/ijret.2014.0304098

Google Scholar